ORVALDI V10 20 30K 3ph/3ph on-line with Power Factor 0.8

Seria: On-line

ORVALDI 3/3 phase series of double-conversion online UPS with a output power factor 0.8. Ranging from 10KVA to 30KVA, it’s designed in small footprints with DSP technology and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Its dual mains inputs will secure the power reliability in power fluctuation area.

Manufacturer: ORVALDI
Product code: V10 20 30 K33
ORVALDI V10 20 30K 3ph/3ph on-line with Power Factor 0.8
ORVALDI V10 20 30K 3ph/3ph on-line with Power Factor 0.8
ORVALDI V10 20 30K 3ph/3ph on-line with Power Factor 0.8

Characteristic:

True double-conversion

  • DSP technology guarantees high performance
  • Output power factor 0.9
  • Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy saving (ECO)
  • Accepts dual-mains inputs (Only for 10K/15K/20K models)
  • Emergency power off function (EPO)
  • Generator compatible
  • SNMP+USB+RS-232 multiple communications
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available

List of applications:

sensitive lab devices

automatics

controll

servers

Technical data:

Model ORVALDI 3/3-10K (L) ORVALDI 3/3-20K (L) ORVALDI  3/3-30K (L)
PHASE 3-phase in / 3-phase out
CAPACITY 10000 VA / 8000 W 20000 VA / 16000 W 30000 VA / 24000 W
INPUT
Nominal Voltage 3 x 400 VAC (3Ph+N)
Input Voltage Range 190-520 VAC (3-phase) at 50% load ; 305-478 VAC (3-phase) at 100% load
Frequency Range 46~54 Hz or 56~64Hz
Power Factor ≧ 0.99 @ 100% Load
OUTPUT
Output Voltage 3 x 400 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦ 2 % THD (Linear Load) ; ≦ 5 % THD (Non-linear Load)
Transfer Time AC Mode to Batt. Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY
AC Mode 90.5% 91.5% 92.1%
ECO Mode 96%
Battery Mode 87% 88% 89%
BATTERY
Standard Model Battery Type 12 V / 9 Ah
Numbers 20 pcs (18 - 20 adjustable)* 20 pcs x 2 strings (18 - 20 adjustable)* 20pcs x 3 strings(18-20 adjustable)*
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (Max.) 1A 2A 4A
Charging Voltage 273 VDC ± 1%
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers  
Charging Current (Max.) 4A 4A 12A
Charging Voltage 273 VDC ± 1%
INDICATORS
LCD Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continously sounding
PHYSICAL
Standard Model Dimension, DxWxH (mm) 815 x 250 x 826 815 x 250 x 826 815 x 300 x 1000
Net Weight (kgs) 109 164 233.5
Long-run Model Dimension, D xWxH (mm) 780 x 250 x 826 780 x 250 x 826 815 x 250 x 826
Net Weight (kgs) 38 40 64
ENVIRONMENT
Humidity 0-95 % RH @ 0- 40°C (Non-condensing)
Noise Level Less than 60dB @ 1 Meter Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser
*When using internal batteries from 18-19, the unit will de-rate according to the below formula: P = PRating x N/20.
Product specifications are subject to change without further notice